dc.contributor.author | Alıç, Taner | |
dc.contributor.author | Fidan, Nurdan | |
dc.contributor.author | Hassa, Ercan | |
dc.contributor.author | Zehir, Sinan | |
dc.date.accessioned | 2023-05-30T07:12:48Z | |
dc.date.available | 2023-05-30T07:12:48Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Alic T, Fidan N, Hassa E, Zehir S. (2023).Is tendinitis in volar plating related to the dorsally protruding screw length and its compartment?. Jt Dis Relat Surg.,34(1):108-114. | en_US |
dc.identifier.issn | 2687-4792 | |
dc.identifier.uri | https://hdl.handle.net/11491/8474 | |
dc.description.abstract | Objectives: The aim of this study was to evaluate the relationship between the length of the protruded screws from the dorsal cortex and extensor tendon damage in all compartments. Patients and methods: Between May 2020 and April 2021, a total of 29 patients (13 males, 16 females; mean age: 52.3±13.0 years; range, 30 to 78 years) who were operated and followed in our clinic for AO A2 and A3 distal radius fractures were included in this prospective study. Surface ultrasound (US) imaging was made to the dorsal sides of both wrists of the operated patients at different timepoints postoperatively. The length of screws with radius dorsal cortex penetration and the presence of tendinitis were recorded. Results: In 15 of 23 patients, the presence of 29 protruding screws was accompanied by tendinitis and, in eight patients, no tendinitis was observed, despite the partial protrusion of screws. A statistically significant correlation was found between the screw protrusion and presence of tendinitis (p1.6 mm and the presence tendinitis (p1.6 mm. Screw penetration can be easily identified with intraoperative US to prevent tendinitis and potential tendon ruptures. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | TURKISH JOINT DISEASES FOUNDATION | en_US |
dc.relation.ispartof | JOINT DISEASES AND RELATED SURGERY | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | * |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | * |
dc.subject | Distal Radius Fracture | en_US |
dc.subject | Extensor Tendon | en_US |
dc.subject | Screw Penetration | en_US |
dc.subject | Tendinitis | en_US |
dc.subject | Ultrasonography | en_US |
dc.subject | Volar Plating | en_US |
dc.title | Is tendinitis in volar plating related to the dorsally protruding screw length and its compartment? | en_US |
dc.type | article | en_US |
dc.department | Hitit Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.authorid | 0000-0003-3848-8577 | en_US |
dc.authorid | 0000-0002-2995-6220 | en_US |
dc.authorid | 0000-0002-0298-7545 | en_US |
dc.authorid | 0000-0003-0644-7826 | en_US |
dc.identifier.volume | 34 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 108 | en_US |
dc.identifier.endpage | 114 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.52312/ jdrs.2023.856 | en_US |
dc.description.wosquality | Q4 | en_US |
dc.description.wospublicationid | WOS:000955617600016 | en_US |
dc.description.pubmedpublicationid | 36700271 | en_US |