dc.identifier.citationGöktas, T., Arkan, M., Özgüven, Ö. F. (2013). A new method to separate broken rotor failures and low frequency load oscillations in three-phase induction motor. 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED), Valencia, Spain.en_US
dc.identifier.isbn9781479900251
dc.identifier.urihttps://doi.org/10.1109/DEMPED.2013.6645706
dc.identifier.urihttps://hdl.handle.net/11491/2077
dc.description2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013, 27 August 2013 through 30 August 2013, Valenciaen_US
dc.description.abstractFor a time-varying loads, the presence of load fluctuation may sometimes have the same effect as broken rotor failure in a stator current of induction motors. In recent years, many methods, which are used to distinguish these two effects, have been published. In this study, a new method, which is based on Analytical Signal Angular Fluctuation (ASAF) signal, is developed to separate effects of load oscillation from broken rotor bar, especially when load oscillation is close to twice slip frequency. The simulation results are presented for the proposed method to show that, discerning broken rotor bar faults from low frequency load oscillation is possible. The developed method is independent of motor parameters. © 2013 IEEE.en_US
dc.description.sponsorship'Generalitat Valenciana-Conselleria d'Educacio, Cultura i Esport';IEEE Power Electronics Society (PELS);SIEMENS;Universitat Politecnica de Valencia (UPV)en_US
dc.language.isoeng
dc.publisherIEEE Computer Societyen_US
dc.relation.isversionof10.1109/DEMPED.2013.6645706en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBroken Rotor Baren_US
dc.subjectFault Detectionen_US
dc.subjectFault Diagnosisen_US
dc.subjectHilbert Transformen_US
dc.subjectInduction Motoren_US
dc.subjectLoad Torque Oscillationen_US
dc.titleA new method to separate broken rotor failures and low frequency load oscillations in three-phase induction motoren_US
dc.typeconferenceObjecten_US
dc.relation.journalProceedings - 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013en_US
dc.departmentHitit Üniversitesi, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümüen_US
dc.identifier.startpage122en_US
dc.identifier.endpage127en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US