Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSeyitoğlu, Sertaç Samed
dc.contributor.authorKılıçarslan, Ali
dc.date.accessioned2019-05-13T09:07:04Z
dc.date.available2019-05-13T09:07:04Z
dc.date.issued2018
dc.identifier.citationSeyitoğlu, S. S., Kılıçarslan, A. (2018). Investigation of the component exergy efficiencies of a two stage vapour compression cycle. International Journal of Exergy, 27(1), 43-61.en_US
dc.identifier.issn1742-8297
dc.identifier.urihttps://doi.org/10.1504/IJEX.2018.093899
dc.identifier.urihttps://hdl.handle.net/11491/1715
dc.description.abstractThe exergy efficiencies of the components (compressor I and II, condenser, evaporator and flash tank) of a two stage vapour compression refrigeration cycle were analysed with respect to evaporator and condenser temperatures for various refrigerants such a R1234ze, R1234yf, R236fa, R227ea and R134a. In the analysis, a computer program was developed by means of engineering equation solver (EES). The exergy efficiencies of components such as the evaporator, condenser, flash tank and compressor I increased while the exergy efficiency of compressor II decreased for the refrigerants used in the cycle for the evaporator temperatures ranging between -30°C to 0°C. The exergy efficiencies of the components such as compressor I and II increased while the exergy efficiency of condenser decreased, and the exergy efficiency of the evaporator stayed almost constant for the refrigerants used in the cycle for the condenser temperatures ranging between 40°C and 55°C. For all refrigerants, the highest exergy efficiencies (around 0.99) were obtained in the flash tank of the cycle while the lowest ones (around 0.15) were obtained in the condenser. © 2018 Inderscience Enterprises Ltd.en_US
dc.language.isoeng
dc.publisherInderscience Enterprises Ltd.en_US
dc.relation.isversionof10.1504/IJEX.2018.093899en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectExergy Efficiencyen_US
dc.subjectR1234yfen_US
dc.subjectR1234zen_US
dc.subjectR134aen_US
dc.subjectR227eaen_US
dc.subjectR236faen_US
dc.subjectTwo-Stageen_US
dc.subjectVapour Compression Refrigerationen_US
dc.titleInvestigation of the component exergy efficiencies of a two stage vapour compression cycleen_US
dc.typearticleen_US
dc.relation.journalInternational Journal of Exergyen_US
dc.departmentHitit Üniversitesi, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.identifier.volume27en_US
dc.identifier.issue1en_US
dc.identifier.startpage43en_US
dc.identifier.endpage61en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US