dc.contributor.author | Tamahkar Irmak, Emel | |
dc.contributor.author | Bakhshpour, Monireh | |
dc.contributor.author | Andaç, Müge | |
dc.contributor.author | Denizli, Adil | |
dc.date.accessioned | 2019-05-13T09:03:45Z | |
dc.date.available | 2019-05-13T09:03:45Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Tamahkar, E., Bakhshpour, M., Andaç, M., Denizli, A. (2017). Ion imprinted cryogels for selective removal of Ni (II) ions from aqueous solutions. Separation and Purification Technology, 179, 36-44. | en_US |
dc.identifier.issn | 1383-5866 | |
dc.identifier.uri | https://doi.org/10.1016/j.seppur.2016.12.048 | |
dc.identifier.uri | https://hdl.handle.net/11491/1529 | |
dc.description.abstract | In this article, ion imprinted poly(hydroxyethyl methacrylate) (PHEMA) based supermacroporous cryogels were synthesized in the presence of a functional monomer, namely N-methacryloyl-histidine methyl ester (MAH), to be complexed with Ni(II) ions. Two types of cryogels (MIP1 and MIP2) were synthesized according to functional monomer/template [MAH/Ni(II)] complexing molar ratios. These cryogels were then characterized by swelling tests, FT-IR and SEM measurements and used for selective binding of Ni(II) ions from aqueous solutions and a certified material. The maximum adsorption capacities of MIP1 and MIP2 cryogels were found as 1.89 and 5.54 mg/g, respectively. Ni(II) imprinted cryogels exhibited excellent selectivity toward competitive metal ions [Fe(III), Cu(II) and Zn(II)] indicating important potential for selective removal of Ni(II) ions from aqueous solutions. In addition, Ni(II) imprinted cryogels were used repeatedly without a decrement in the binding capacity. © 2016 Elsevier B.V. | en_US |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | en_US |
dc.relation.isversionof | 10.1016/j.seppur.2016.12.048 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cryogels | en_US |
dc.subject | Ion Imprinting | en_US |
dc.subject | Nickel Ions | en_US |
dc.title | Ion imprinted cryogels for selective removal of Ni(II) ions from aqueous solutions | en_US |
dc.type | article | en_US |
dc.relation.journal | Separation and Purification Technology | en_US |
dc.department | Hitit Üniversitesi, Mühendislik Fakültesi, Kimya Mühendisliği Bölümü | en_US |
dc.identifier.volume | 179 | en_US |
dc.identifier.startpage | 36 | en_US |
dc.identifier.endpage | 44 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |