Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorŞanlı, Senem
dc.contributor.authorPalabıyık, İsmail M.
dc.contributor.authorŞanlı, Nurullah
dc.contributor.authorGüzel Seydim, Zeynep B.
dc.contributor.authorAlsancak, Güleren
dc.date.accessioned2019-05-13T08:59:01Z
dc.date.available2019-05-13T08:59:01Z
dc.date.issued2011
dc.identifier.citationŞanlı, S., Palabıyık, İ. M., Şanlı, N., Güzel Seydim, Z. B., Alsancak, G. (2011). Optimization of the experimental conditions for macrolide antibiotics in high performance liquid chromatography by using response surface methodology and determination of tylosin in milk samples. Journal of Analytical Chemistry, 66(9), 838-847.en_US
dc.identifier.issn1061-9348
dc.identifier.urihttps://doi.org/10.1134/S1061934811090152
dc.identifier.urihttps://hdl.handle.net/11491/1238
dc.description.abstractThe simple, rapid and sensitive liquid chromatographic separation of five macrolides (tilmicosin, erythromycin, tylosin, roxithromycin and josamycin) widely used in food producing animals was developed. Response surface methodology was used as an optimization method of mobile phase, column temperature and pH to provide the best resolution of these analytes. The separation was performed by using an end-capped X-Terra RP-18 column (250 × 4.6 mm I.D × 5 m) with an isocratic system of 15 mM hydrochloric acid (pH 2.5)-acetonitrile as the mobile phase at a temperature of 30°C and flow-rate of 1.0 mL/min. The suitability of the method for multi-residue determination of the macrolides is demonstrated by the analysis of milk samples spiked with tylosin. Roxithromycin was used as internal standard. The recovery of tylosin was quite good as 90.8%. The limit of quantification and detection limit were 0.024 and 0.007 ?g/mL, respectively. The method was successfully applied to determination of macrolides at levels below the maximum concentration legally allowed in milk samples. © 2011 Pleiades Publishing, Ltd.en_US
dc.language.isoeng
dc.relation.isversionof10.1134/S1061934811090152en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAntibiotic Residuesen_US
dc.subjectLiquid Chromatographyen_US
dc.subjectMacrolidesen_US
dc.subjectMilken_US
dc.subjectResponse Surface Methodologyen_US
dc.titleOptimization of the experimental conditions for macrolide antibiotics in high performance liquid chromatography by using response surface methodology and determination of tylosin in milk samplesen_US
dc.typearticleen_US
dc.relation.journalJournal of Analytical Chemistryen_US
dc.departmentHitit Üniversitesi, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.identifier.volume66en_US
dc.identifier.issue9en_US
dc.identifier.startpage838en_US
dc.identifier.endpage847en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster