Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorBilgin, Elif
dc.contributor.authorErol, Kadir
dc.contributor.authorKöse, Kazım
dc.contributor.authorKöse, Dursun Ali
dc.date.accessioned2019-05-13T08:58:14Z
dc.date.available2019-05-13T08:58:14Z
dc.date.issued2018
dc.identifier.citationBilgin, E., Erol, K., Köse, K., Köse, D. A. (2018). Use of nicotinamide decorated polymeric cryogels as heavy metal sweeper. Environmental Science and Pollution Research, 25(27), 27614-27627.en_US
dc.identifier.issn0944-1344
dc.identifier.urihttps://doi.org/10.1007/s11356-018-2784-6
dc.identifier.urihttps://hdl.handle.net/11491/1096
dc.description.abstractCryogels are synthetic polymers used in adsorption experiments in recent years. Because of their macropores, they provide an excellent advantage as an adsorbent in continuous and batch adsorption processes. In this study, nicotinamide (NAA) decorated poly(2-hydroxyethyl methacrylate-glycidyl methacrylate), poly(HEMA-GMA), cryogels were synthesized. Heavy metal adsorption was carried out in wastewater obtained from six different sources in Çorum, Turkey. This study has a novelty regarding the application, i.e., it is the first time to use a polymeric adsorbent for the removal of 15 different heavy metal at the same time without any competition (despite the fact that there is a competition between the metals, the only thing is the removal regarding the purpose the study) as a heavy metal sweeper. Inductively coupled plasma-mass spectrometer (ICP-MS) was used for the determination of the initial amount of heavy metal in the wastewater samples. Adsorption studies were performed using poly(HEMA-GMA) and NAA-decorated poly(HEMA-GMA) cryogel to see the effect of NAA decoration. Higher adsorption capacity was achieved using NAA decorated poly(HEMA-GMA) cryogel. The total heavy metal amount adsorbed from six different sources was about 686 and 387 mg for poly(HEMA-GMA)-NAA and poly(HEMA-GMA) cryogels, respectively. The highest heavy metal adsorption value was obtained in the wastewater from source 2, and Zn (II) was the heavy metal adsorbed most for both cryogel. Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), thermal, surface area, elemental, and computerized microtomography (μCT) analyses were used for the characterization of cryogels.en_US
dc.language.isoeng
dc.publisherSpringer Verlagen_US
dc.relation.isversionof10.1007/s11356-018-2784-6en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAdsorptionen_US
dc.subjectCryogelen_US
dc.subjectHeavy Metalen_US
dc.subjectNicotinamideen_US
dc.subjectWastewateren_US
dc.titleUse of nicotinamide decorated polymeric cryogels as heavy metal sweeperen_US
dc.typearticleen_US
dc.relation.journalEnvironmental Science and Pollution Researchen_US
dc.departmentHitit Üniversitesi, Fen Edebiyat Fakültesi, Kimya Bölümüen_US
dc.authorid0000-0003-4767-6799en_US
dc.authorid0000-0003-1467-2898en_US
dc.identifier.volume25en_US
dc.identifier.issue27en_US
dc.identifier.startpage27614en_US
dc.identifier.endpage27627en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster